KEBOS POWER ,to continue a better life.

GH11 TX 6- 10KVA & GH31 TX 10-20KVA

GH11 TX 6K- 10KVA & GH31 TX 10K-20KVA are High frequency online UPS is transformer based, which address the customers' needs for high reliability, stability, stability and quality. Features with double conversion topology, input harmonic filter, IBGT based SPWM inverter, GH11 TX  & GH31 TX series offer load perfect Sine wave to fulfill all kinds of businesses' requirement for highly reliable, highly stable, high quality, uninterruptible power supply.

  • True double-conversion

  • Input power factor correction

  • Output power factor 0.8

  • Wide input voltage

  • Converter mode available

  • Generator compatible

  • Adjustable charging current via LCD or software(1A-6A)

  • Smart SNMP works well with either USB or RS-232 together

  • Comprehensive display allows easy monitoring and access of UPS status

  • Emergency power off function(EPO)

Drag the table to right or left to view more.
MODELGH11 TX-6K (L)GH11 TX-10K (L)GH31 TX-10KLGH31 TX-15KLGH31 TX-20KL
PHASESingle phase with ground
CAPACITY6000VA /4800W10000VA/8000W10000VA/8000W15000VA/12000W20000VA/16000W
INPUT
Nominal Voltage 200/208/220/230/240VAC3 x 400 VAC (3Ph+N)
Input Voltage Range  110-300VAC at 50% load 176-300VAC at 100% load 190-520 VAC (3-phase) @ 50% load
305-520 VAC (3-phase) @ 100% load

46-54Hz @50Hz / 56-64Hz@60Hz
Power Factor≧0.99 @ Nominal Voltage (100% load)
OUTPUT
Output Voltage104/110/115/120VAC or 208/220/230/240VAC
Voltage Regulation± 1%
Frequency Range (Synchronized Range)46-54Hz @50Hz / 56-64Hz@60Hz
Frequency Range (Batt. Mode)50Hz±0.1Hz or 60Hz±0.1Hz 
Current Crest Ratio3:1
Harmonic Distortion≦ 3 % THD (Linear Load)             
≦ 5 % THD (Non-linear Load)
Transfer TimeAC to DC0ms
Inverter to Bypass0ms
Wave Form (Batt. Mode)Pure Sine wave
EFFICIENCY
To AC Mode84%89%83%
To Battery Mode82%87%83%
BATTERY
Standard ModelBattery Type12 V /7 AH12 V / 9AH/
Numbers1616
Typical Recharge Time9 hours recover to 90% capacity
Charging Current (max.)Default:1.0 A,1.0A,2.0A (Adjustable)/
Charging Voltage218.4 VDC ±1%
Long-run Model*Battery TypeDepending on the capacity of external batteries
Numbers1616161616
Charging Current (max.)Default:4.0 A,  1.0A/2.0A/4.0A/6.0 A (Adjustable)
Charging Voltage218.4 VDC ±1%
INDICATORS
LCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
Standard ModelDimension, D x W x H (mm)466*250*826592*250*826/
Net Weight (kgs)106118
Long-run Model*Dimension, D x W x H (mm)369*190*630592*250*826815*250*826
Net Weight (kgs)63.58790124128
ENVIRONMENT
Humidity0-90% RH@0-50°C (non-condensing)
Noise LevelLess than 55 DB @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
* Product specifications are subject to change without further notice