KEBOS POWER ,to continue a better life.

GHD33 Ⅲ 15-100KVA LV

GHD33 III LV series Online UPS from 15K -100KVA, is specially designed with pluggable power module and front access to simplify maintenance. Its power walk-in function optimize parallel operation up to 6 units even with generator input.

  • True double-conversion

  • DSP technology guarantees high performance

  • Output power factor 1.0

  • Active power factor correction in all phases

  • 50Hz/60Hz frequency converter mode

  • ECO mode operation for energy saving (ECO)

  • Emergency power off function (EPO)

  • Generator compatible

  • SNMP+USB+RS-232 multiple communications

  • 3-stage extendable charging design for optimized battery performance

  • Adjustable battery numbers for long-run model

  • Maintenance bypass available

  • Parallel operation with commom battery

  • Power walk-in function

  • Optional isolation transformer offers full isolation and complete common mode noise rejection

Drag the table to right or left to view more.
MODELGHD33 III-15KLGHD33 III-30KLGHD33 III- 50KLGHD33 III-60KLGHD33 III-90KLGHD33 III-100KL
PHASE3-phase in/3-phase out
CAPACITY15KVA/15KW30KVA/30KW50KVA/50KW60KVA/60KW90KVA/90KW100KVA/100KW
PARALLEL CAPABILITY4
INPUT
Nominal Voltage3 x 208/220 VAC (3Ph+N)
Voltage Range70-156 VAC  @ 50% load ; 88-146 VAC @ 100% load
Frequency Range40~70 Hz
Power Factor≧ 0.99  @ 100% load
Harmonic Distortion (THDi)< 4% at full linear load
OUTPUT
Output Voltage3 x 208/220 VAC (3Ph+N) 
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)50/60 Hz ± 1%
Current Crest Ratio3:1 (max.)
Harmonic Distortion≦2% THD (Linear Load)
≦5% THD (Non-linear Load)
Transfer TimeAC mode to Battery modezero
Inverter to Bypasszero
Wave Form (Batt. Mode)Pure Sine Wave
Overload Capability100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% for 400ms
BYPASS
Nominal Voltage3 x 208/220 VAC (3Ph+N)
Voltage Range305VAC~457VAC
Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
Overload Capability100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% for 400ms
EFFICIENCY
AC Mode93.5%
ECO Mode98.5%
Battery Mode92.5%
BATTERY
Battery TypeDepending on application
Numbers32~40 pcs (Adjustable)
Charging Current (max.)1-12A, Adjustable1-18A, Adjustable2-36A, Adjustable3-54A, Adjustable
Charging Voltage+/-13.65V*N  (N = 16~20)
INDICATORS
Touch  color LCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
PHYSICAL
Dimension, D X W X H (mm)815 x 300 x 1000815 x 300 x 1000974 x 600 x 1600
Net Weight (kgs)7487241286286382
ENVIRONMENT
Operation Temperature0-40°C
Operation Humidity<95% and non-condensing
Altitude**0 ~ 1000m at full load
Noise LevelLess than 65 dB @ 1 MeterLess than 70 dB @ 1 MeterLess than 75 dB @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
**If the UPS is installed or used in a place where the altitude is higher than maximum height, the output power will be derated 1% per 100m.
Product specifications are subject to change without further notice.