KEBOS POWER ,to continue a better life.
KH-I VII WP -a hybrid inverter features IP65 ratedenclosure.IP65 water and dust resistance provide excellent protection under diverse climates. KH-I VII WP hybrid inverter is able to install in areas that are likely to suffer from sand and water penetration. User-programmable priority for PV, battery, and grid; and more via software, suits your need for that point in time of day or night. It helps to manage self-consumption and reduce electricity bills.
Pure sine wave output
IP65 waterproof and dustproof makes the inverter available for various working conditions
Self-consumption and Feed-in to the grid
Programmable supply priority for PV, Battery or Grid
Reserved communication port for BMS (RS485)
User-adjustable charging current and voltage
Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
Monitoring software for real-time status display and control
Parallel operation up to 9 units
MODEL | KH-I VII WP 2KW | KH-I VII WP 3KW | KH-IVII WP 5KW | KH-I VII WP 6KW |
---|---|---|---|---|
PHASE | 1-phase in / 1-phase out | |||
Maximum PV Input Power | 3000W | 4500W | 6000W | 6500W |
Rated Output Power | 2000VA/2000W | 3000VA/3000W | 5000VA/5000W | 6000VA/6000W |
Maximum Charging Power | 2000W | 3000W | 4000W | 6000W |
GRID-TIE OPERATION | ||||
PV INPUT (DC) | ||||
Maximum DC Voltage | 400 VDC | 500 VDC | 500 VDC | 550 VDC |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 150 VDC | 120VDC / 150 VDC | ||
MPP Voltage Range | 120 VDC ~ 400 VDC | 120 VDC ~ 450 VDC | 120 VDC ~ 450 VDC | 120 VDC ~ 450 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 13A | 1 / 18A | 1 / 27A | 1 / 27A |
GRID OUTPUT (AC) | ||||
Nominal Output Voltage | 220/230/240 VAC | |||
Output Voltage Range | 184 - 264.5 VAC or 195.5 - 253 VAC or 184 ~ 264.5 VAC (Selectable) | |||
Nominal Output Current | 8.7A | 13A | 21.7A | 26A |
Power Factor | >0.99 | |||
EFFICIENCY | ||||
Maximum Conversion Efficiency (DC/AC) | 95% | 96% | ||
OFF-GRID OPERATION | ||||
AC INPUT | ||||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC | |||
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC | |||
Frequency Range | 50 Hz/60 Hz (Auto sensing) | |||
Maximum AC Input Current | 20A | 30A | 40 A | 40 A |
PV INPUT (DC) | ||||
Maximum DC Voltage | 400 VDC | 500 VDC | 500 VDC | 550 VDC |
MPP Voltage Range | 120 VDC ~ 400 VDC | 120 VDC ~ 450 VDC | 120 VDC ~ 450 VDC | 120 VDC ~ 450 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 13A | 1 / 18A | 1 / 27A | 1 / 27A |
BATTERY MODE OUTPUT (AC) | ||||
Nominal Output Voltage | 220/230/240 VAC | |||
Output Waveform | Pure sine wave | |||
Efficiency (DC to AC) | 93% | |||
HYBRID OPERATION | ||||
PV INPUT (DC) | ||||
Maximum DC Voltage | 400 VDC | 500 VDC | 500 VDC | 550 VDC |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 150 VDC | |||
MPP Voltage Range | 120 VDC ~ 400 VDC | 120 VDC ~ 450 VDC | 120 VDC ~ 450 VDC | 120 VDC ~ 450 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 13A | 1 / 18A | 1 / 27A | 1 / 27A |
GRID OUTPUT (AC) | ||||
Nominal Output Voltage | 220/230/240 VAC | |||
Output Voltage Range | 184 - 264.5 VAC or 195.5 - 253 VAC or 184 ~ 264.5 VAC (Selectable) | |||
Nominal Output Current | 8.7A | 13A | 21.7A | 26A |
AC INPUT | ||||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC | |||
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC | |||
Maximum AC Input Current | 20A | 30A | 40 A | 40 A |
BATTERY MODE OUTPUT (AC) | ||||
Nominal Output Voltage | 220/230/240 VAC | |||
Output Waveform | Pure sine wave | |||
Efficiency (DC to AC) | 93% | |||
BATTERY & CHARGER | ||||
Nominal DC Voltage | 48 VDC | |||
Maximum Solar Charging Current | 40 A | 60 A | 100 A | 120 A |
Maximum AC Charging Current | 40 A | 60 A | 100 A | 120 A |
Maximum Charging Current | 40 A | 60 A | 100 A | 120 A |
GENERAL | ||||
PHYSICAL | ||||
Dimension, D X W X H (mm) | 196 x 360 x 665 | |||
Net Weight (kgs) | 22.5 | |||
INTERFACE | ||||
Parallel Function | Yes, 9 units | |||
Communication Port | USB or RS-232/Dry Contact/RS485 | |||
ENVIRONMENT | ||||
Humidity | 0 ~ 95% RH (No condensing) | |||
Operating Temperature | -25°C to 50°C |