KEBOS POWER ,to continue a better life.

KH-I -V IV WP 3-6KW

KH-I-V IV WP - a hybrid inverter features IP65 ratec enclosure.IP65 water and dust resistance provide excellent protection under diverse climates. KH-I-V IV WP hybrid inverter is able to install in areas that are likely to suffer from sand and water penetration. User-programmable priority for PV, battery, and grid; and more via software, suits your need for that point in time of day or night. It helps to manage self-consumption and reduce electricity bills.

  • Pure sine wave output

  • IP65 waterproof and dustproof makes the inverter available for various working conditions

  • Self-consumption and Feed-in to the grid

  • Programmable supply priority for PV, Battery or Grid

  • Built-in communication port for BMS (RS485), Wi-Fi

  • User-adjustable charging current and voltage

  • Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup

  • Dual output for smart load control

  • Parallel operation up to 9 units


Drag the table to right or left to view more.
MODELKH-I-V IV WP 3KWKH-I-V IV WP 5KWKH-I-V IV WP 6KW
PHASE1-phase in / 1-phase out
Maximum PV Input Power3000W5000W6500W
Rated Output Power3000VA/3000W5000VA/5000W6000VA/6000W
Maximum Charging Power3000W5000W6000W
GRID-TIE OPERATION
PV INPUT (DC)
Maximum DC Voltage500 VDC500 VDC550 VDC
Start-up Voltage / Initial Feeding Voltage120VDC / 150 VDC
MPP Voltage Range120 VDC ~  450 VDC
Number of MPP Trackers
/ Maximum Input Current 
1 / 18A1 / 27A1 / 30A
GRID OUTPUT (AC)
Nominal Output Voltage220/230/240 VAC
Output Voltage Range184 - 264.5 VAC or 195.5 - 253 VAC or 184 - 264.4 VAC (Selectable)
Nominal Output Current13A21.7A26A
Power Factor>0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range90 - 280 VAC or 170 - 280 VAC
Frequency Range50 Hz/60 Hz (Auto sensing)
Maximum AC Input Current30A40A40A
PV INPUT (DC)
Maximum DC Voltage500 VDC500 VDC550 VDC
MPP Voltage Range 120VDC / 150 VDC
Number of MPP Trackers
/ Maximum Input Current 
1 / 18A1 / 27A1 / 30A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage220/230/240 VAC
Output WaveformPure sine wave
Efficiency (DC to AC)93%93%93%
HYBRID OPERATION
PV INPUT (DC)
Maximum DC Voltage500 VDC500 VDC550 VDC
Start-up Voltage / Initial Feeding Voltage120VDC / 150 VDC
MPP Voltage Range120 VDC ~  450 VDC
Number of MPP Trackers
/ Maximum Input Current 
1 / 18A1 / 27A1 / 30A
GRID OUTPUT (AC)
Nominal Output Voltage220/230/240 VAC
Output Voltage Range184 - 264.5 VAC or 195.5 - 253 VAC or 184 - 264.4 VAC (Selectable)
Nominal Output Current13A21.7A26A
AC INPUT
AC Start-up Voltage / Auto Restart Voltage120 - 140 VAC / 180 VAC
Acceptable Input Voltage Range90 - 280 VAC or 170 - 280 VAC
Maximum AC Input Current30A40A40A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage220/230/240 VAC
Output WaveformPure sine wave
Efficiency (DC to AC)93%93%93%
BATTERY & CHARGER
Nominal DC Voltage48 VDC
Maximum Solar Charging Current60 A100 A120 A
Maximum AC Charging Current60 A100 A120 A
Maximum Charging Current60 A100 A120 A
GENERAL
PHYSICAL
Dimension, D X W X H (mm)192 x 360 x 665
Net Weight (kgs)22.522.522.5
INTERFACE
Parallel FunctionYes, 9 units
Communication  PortUSB or RS-232/Dry Contact/RS485/Wi-Fi
ENVIRONMENT
Humidity0 ~ 95% RH (No condensing)
IP degreeIP65
Operating Temperature-25°C to 50°C